DC electronic device circuit breakers protect your equipment from overload and short-circuit currents, and selectively close affected circuits in the event of a fault. This model has 4 channels, each with a corresponding knob for easy adjustment of its overload current. It is divided into 6 gears: 2, 3, 4, 6, 8, and 10A. Communication interface allows remote monitoring.
Overload warning
When the channel current reaches 0.8 times the set value, the green light flashes to give a warning and the channel works normally.
Overload protection
When the channel current reaches 1.1 times the set value, the yellow light flashes.
But if the current is between 1.1 and 1.3 times, the circuit breaker will activate delay protection. Disconnect the channel and flash the red light after 8 seconds to reduce misoperation caused by transient current peaks. If the channel current reaches 1.3 times the set value, it will directly enter overload protection, disconnect the channel, and the red light will flash.
Short circuit protection
This is the highest level of protection used to deal with severe short circuit situations, where the current far exceeds the normal operating current. Once this abnormal current is detected, the circuit breaker will immediately trip, quickly cutting off the circuit and preventing serious consequences such as equipment damage or fire. Instantaneous protection is crucial for protecting circuits and equipment from extreme current surges.
ZR - ECB - M - 04 - 24DC / 06 - XXX
1 2 3 4 5 6 7
1 | Code | ZR: ZERO |
2 | Series Node | ECB: Electronic circuit breaker |
3 | Communication Method | N: Dry contact normally closed output |
M: MODBUS 485 communication only | ||
4 | Number of Channels | 04: 4 Channels |
5 | Rated Voltage | 24DC: 24V DC |
6 | Current Rating | 06: Rated current 6A |
7 | Customization |
Model Number | ZR-ECB-N (M)-04-24VDC/10-000 | ZR-ECB-N (M)-04-48VDC/10-000 |
Installation Type | Standard DIN35mm rail mounting, 1 bit | |
Type of Product | Device (overload) circuit breaker | |
Protection Channel | 4 | |
Insulation Protection Class | 3 | |
Level of Pollution | 2 | |
Width | 44.5mm | |
Height | 90.5mm | |
Depth | 94mm (including DIN7.5mm type guide rail) | |
Operating Voltage Range | 18VDC---30VDC | 45VDC---51VDC |
Rated Operating Voltage | 24VDC | 48VDC |
Total Fixed Current | Max.40ADC (DC IN) | |
Single Channel Rated Current | 2/3/4/6/8/10A | |
Main Power Input | For example, DC 24V+ | For example, DC 48V+ |
Main Loop Ground | GND | |
Single Control Output | DC (+) terminal device input, each channel is the same | |
Single Road Common Ground | The DC (-) ground terminal is connected to the device in common ground | |
Relay Dry Junction Output | Normally closed, open if all channel is ON, used to control the input signal | |
RS485 Communication Line | Slave, connected to the master controller (such as PLC) | |
Jumper (Connector) Model | TJA6.2 | |
Preset Current | 2-10A | |
Rated Surge Voltage | 0.5 kV | |
Type of Tripping | E (electronic type) | |
Product Power Consumption | The static value is less than 0.5W | |
Module Initialization Time | The power on time is less than 50ms | |
Cooldown Time After Shutdown | Less than 30 s | |
Current Measurement Error | Less than 10% | |
MTBF (IEC61709, SN29500) | Product life 600Kh |
Q: Whether some samples can be provided?
A: Yes, We can supply the sample if we have ready parts in stock, but the customers have to pay the sample cost and the courier cost.
Q: What is your terms of payment?
A: T/T 70% as deposit, and 30% before delivery. We'll show you the photos of the products and packages before you pay the balance.
Q: How about your delivery time?
A: Generally, it will take 5-7 days after receiving your advance payment. The specific delivery time depends on the items and the quantity of your order.