Space-Saving Mini Circuit Breaker for Low Voltage Applications

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of US$ 50/Piece
Request Sample
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (23)
  • Space-Saving Mini Circuit Breaker for Low Voltage Applications
  • Space-Saving Mini Circuit Breaker for Low Voltage Applications
  • Space-Saving Mini Circuit Breaker for Low Voltage Applications
  • Space-Saving Mini Circuit Breaker for Low Voltage Applications
  • Space-Saving Mini Circuit Breaker for Low Voltage Applications
  • Space-Saving Mini Circuit Breaker for Low Voltage Applications
Find Similar Products
  • Overview
  • Product Description
  • Application Scope
  • Part Number Definition
  • Product Parameters
  • Company Profile
  • Certifications
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
ZR-ECB-M-01-12DC/10
Arc-extinguishing Medium
DC Production
Installation
Fixed
Structure
Ecb
Poles Number
DC Production
Type
Circuit Breaker
Function
Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
CE
Protection Grade
IP20
Plug Time
<1ms
Communication Type
Dry Contact
Flame Retardant Rating
UL94 V-0
Transport Package
Carton
Specification
72*6*90
Trademark
ZERO
Origin
China

Product Description

Space-Saving Mini Circuit Breaker for Low Voltage Applications 
Product Description

Our single channel electronic device protector is ideal solution for selective protection of system components in DC applications. Its width is only 6mm, greatly saving space in the cabinet. The single channel DC electronic circuit breaker has an adjustable output current range of 1-10A, which can be flexibly adjusted according to different load requirements. Electronic circuit breakers not only support dry node signals, but are also compatible with Modbus serial communication, allowing you to remotely read data and control it.
Space-Saving Mini Circuit Breaker for Low Voltage ApplicationsSpace-Saving Mini Circuit Breaker for Low Voltage ApplicationsSpace-Saving Mini Circuit Breaker for Low Voltage Applications

Application Scope

 

  1. - 24V DC power supply output side
  2. - 24v DC current distribution
  3. - Protect for PLC, solenoid valve, sensor, actuator, etc
 
Part Number Definition

ZR - ECB - N - 01 - 24DC / 10
 1        2      3     4       5         6

 
1 Code ZR: ZERO
2 Series Code ECB: Electronic circuit breaker
3 Communication Method N: Dry contact normally closed output
    M: MODBUS 485 communication only
4 Number of Channels 01: This type has only one channel
5 Rated Voltage 24DC: 24V DC(12V, 48V is Optional)
6 Current Rating 10: Rated current 10A, it can be selected 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
(If 6A is optional, set parameters 1, 2, 3, 4, 5, and 6A)
 
Product Parameters
Model Number ZR-ECB-01-12VDC/10-000 ZR-ECB-01-24VDC/10-000
Installation Type Standard DIN35mm rail mounting, 1 bit
Type of Product Device (overload) circuit breaker
Protection Channel 1
Insulation Protection Class 3
Level of Pollution 2
Width 6mm
Height 90mm
Depth 72mm (including DIN7.5mm type guide rail)
Operating Voltage Range 9VDC---15VDC 18VDC---30VDC
Rated Operating Voltage 12VDC 24VDC
Total Fixed Current Max.10ADC (DC IN)
Single Channel Rated Current Less than 10A
Main Power Input For example, DC 12V+ For example, DC 24V+
Main Loop Ground GND
Single Control Output DC (+) terminal device input, each channel is the same
Single Road Common Ground The DC (-) ground terminal is connected to the device in common ground
Relay Dry Junction Output Normally closed
RS485 Communication Line Slave, connected to the master controller (such as PLC)
Jumper (Connector) Model TJA6.2
Preset Current 1-10A
Rated Surge Voltage 0.5 KV
Type of Tripping E (electronic type)
Product Power Consumption The static value is less than 0.5W
Module Initialization Time The power on time is less than 50ms
Cooldown Time After Shutdown Less than 30 S
Current Measurement Error Less than 5%
MTBF (IEC61709, SN29500) Product life 600Kh
 
Company Profile

Space-Saving Mini Circuit Breaker for Low Voltage ApplicationsSpace-Saving Mini Circuit Breaker for Low Voltage Applications

 
Certifications

Space-Saving Mini Circuit Breaker for Low Voltage Applications

Packaging & Shipping

Space-Saving Mini Circuit Breaker for Low Voltage Applications

 

 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier