Modbus RTU Remote Io Communication Module

Product Details
Customization: Available
Task: Data Collect
Structure: Combination
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (23)
  • Modbus RTU Remote Io Communication Module
  • Modbus RTU Remote Io Communication Module
  • Modbus RTU Remote Io Communication Module
  • Modbus RTU Remote Io Communication Module
  • Modbus RTU Remote Io Communication Module
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Certifications
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
XC-ET01-0004A
Mathematical Model
Data Collect
Signal
Continuous
Function
Automatic Control, Protection, Monitoring, Measurement
Certification
CE
Condition
New
Customized
Customized
Material
Engineering Plastics
Supply Voltage
DC24V(-25%~+30%)
System Current Consumption
4mA
Electrical Isolation Between Channels
Not Isolated
Channel and Auxiliary Power Electrical I
Isolate
Electrical Isolation Between Channel and
Isolate
Transport Package
Carton
Specification
12*105.7*83.95
Trademark
Hostlink
Origin
China

Packaging & Delivery

Package Size
75.00cm * 35.00cm * 35.00cm
Package Gross Weight
16.000kg

Product Description

Modbus RTU Remote IO Communication Module
Product Description

The plug-in IO module is an expandable distributed IO module that supports multiple bus communication protocols. It adopts a combination structure of couplers and I0 modules, and a single coupler can expand up to 32 IO modules; Installation is more convenient, using a 35mm standard guide rail for easy disassembly from the rail without the need for any tools. Compared to traditional wiring methods, direct insertion wiring technology greatly shortens wiring time while ensuring the safety and reliability of wiring.

Product Parameters

Modbus RTU Remote Io Communication Module

Modbus RTU Remote Io Communication Module

Parameters of Analog Input IO Module


Electrical Parameters
 
Supply Voltage DC24V(-25%~+30%)
System Current Consumption 4mA
Electrical Isolation Between Channel And Backplate Isolate
Channel And Auxiliary Power Electrical Isolation Isolate
Electrical Isolation Between Channels Not isolated
A/D Accuracy of Analog Input 16 bit
Voltage Input Range 0~+10V, 1~5V,-10~+10V,-5~+5V
Current Input Range 0~20mA, 4~20mA
Voltage Type Input Impedance 120kΩ
Current Type Input Impedance (0-20ma) 250kΩ
Maximum Allowable Input Voltage for Voltage Input 30V
Maximum Allowable Input Current for Current Input 50Ma
Length of Wiring Cable Current 600M/1000M (shielded)
Voltage 100M/200M (shielded)
Channel Status Indication/Module Status Indication Yellow LED/Red+Green LED

Physical Parameters
 
Working Temperature -10ºC~+60ºC
Storage Temperature -25ºC~+85ºC
Dimensions (Width/Height/Depth) 8/16 Channel:12*105.7*82.5mm
32 Channel:24*105.7*82.5mm
Allow Humidity 5%~95% No condensation
Protection Level IP20

Parameters of Analog Output IO Module
 
Supply Voltage DC24V(-25%~+30%)
System Current Consumption (DC24V) 4mA
Auxiliary Current Consumption (DC24V) All outputs, maximum 75mA
Electrical Isolation Between Channel And Backplate Isolate
Channel And Auxiliary Power Electrical Isolation Isolate
Electrical Isolation Between Channels Not isolated
Voltage Input Range 0~+10V, 1~5V,-10~+10V,-5~+5V
Current Input Range 0~20mA, 4~20mA
Voltage Output Load Resistance The minimum value of load resistance is 2k Ω; Maximum capacitive load of 1μF
Current Output Load Resistance The maximum load resistance is 500Ω; Inductive load maximum 1mH
External Voltage Damage Limit 30V
Maximum Short-Circuit Current Output 45mA
Length of Wiring Cable Current 600M/1000M (shielded)
Voltage 100M/200M (shielded)
Channel Status Indication/Module Status Indication Yellow LED/Red+Green LED
 
Certifications

 

Modbus RTU Remote Io Communication Module

 
Company Profile

 

Modbus RTU Remote Io Communication ModuleModbus RTU Remote Io Communication Module
Packaging & Shipping


Modbus RTU Remote Io Communication Module
FAQ

Q: Whether some samples can be provided?
A: Yes, We can supply the sample if we have ready parts in stock, but the customers have to pay the sample cost and the courier cost.

Q: What is your terms of payment?
A: T/T 70% as deposit, and 30% before delivery. We'll show you the photos of the products and packages before you pay the balance.

Q: How about your delivery time?
A: Generally, it will take 5-7 days after receiving your advance payment. The specific delivery time depends on the items and the quantity of your order.